VMPX [Ventilation Manager Power eXtended] controllers for the "Seseragi®"
The VMPX controllers regulate power, air supply and exhaust of the
individual fan units.
Various advanced features are available depending on the model, tailored
to your needs.
Central control unit VMPX-N series
The central controller unit VMPX-N series automatically operates when the power is turned on.
Functions of the central control unit VMPX-N series
- Fan exhaust and air supply regulation
- Filter maintenance indication
- 1 controller unit can control 2~8 fan units
Operation Panel
① Power-
supply
② Air flow selection
③ Filter inspection
indicator/ Reset
④ Heat exchange mode
⑤ Nightpurge mode
⑥ Display air flow intensity
①
②
③
④
⑤
⑥
- ① Power supply
- ② Air flow selection
- ③ Filter inspection indicator/ Reset
- ④ Heat exchange mode
- ⑤ Nightpurge mode
- ⑥ Display air flow intensity
① Press the power supply for approx. 5 seconds to switch the device on/off.
② With the centralized controller VMPX-AQ, by pressing the air flow selection button, you can operate the
machine in four different modes.
③
When the LED of the filter inspection sign lights up, inspect the filter. After inspection, press and hold the
button ③ for about 3 seconds to reset the maintenance interval.
④ The heat exchange mode is the default operating mode.
⑤ This button is used to change to night purge mode.
⑥ According to the selected level of airflow intensity, up to 4 LEDs light up. Level 1 and 2 are the usual
levels. If the kitchen is used for family celebrations, barbecues or similar, level 2 is recommended. (The
shortest indicator LED represents level 1, the others represent levels 2-4, with level 4 being the longest).
Central control unit VMPX-NH series
Live in the comfort zone due to the VMPX-NH controller with humidity regulation
Influences of the surrounding temperature and humidity factors on the human body
Automatic adjustment of operation time
The humidity in the air gets absorbed on the surface of the heat storage element of the "Seseragi®" as it passes through. Moisture absorption rates are high immediately after reversing the fan's rotation, but decrease soon thereafter. Following these characteristics, it is possible to adjust the humidity levels of the house by tuning the timing of the inversion intervals. The humidity sensor controls the indoor humidity levels by regulating the inversion intervals to 15-140 seconds.
Operation Panel
LED color change humidity indicator rH[%]
humid
comfort zone
arid
① Power-
supply
② Air flow selection
③ Filter inspection
indicator/ Reset
④ Heat exchange mode
⑤ Nightpurge mode
⑥ Display air flow intensity
①
②
③
④
⑤
⑥
- ① Power supply
- ② Air flow selection
- ③ Filter inspection indicator/ Reset
- ④ Heat exchange mode
- ⑤ Nightpurge mode
- ⑥ Display air flow intensity
① Press the power supply for approx. 5 seconds to switch the device on/off.
② With the centralized controller VMPX-AQ, by pressing the air flow selection button, you can operate the
machine
in four different modes.
③
When the LED of the filter inspection sign lights up, inspect the filter. After inspection, press and hold the
button ③ for about 3 seconds to reset the maintenance interval.
④ The heat exchange mode is the default operating mode.
⑤ This button is used to change to night purge mode.
⑥ According to the selected level of airflow intensity, up to 4 LEDs light up. Level 1 and 2 are the usual
levels. If the kitchen is used for family celebrations, barbecues or similar, level 2 is recommended. (The
shortest indicator LED represents level 1, the others represent levels 2-4, with level 4 being the longest).
The central controller unit VMPX-NH series automatically operates when the power is turned on.
Functions of the central control unit VMPX-NH series
- Fan exhaust and air supply regulation
- Automatic humidity adjustment
- Filter maintenance indication
- 1 controller unit can control 2~8 fan units
Central Controller VMPX-AQ Series
Living in a comfort zone thanks to the VMPX-AQ Controller with CO₂ regulation functionality
Automatic air flow adjustment mode
The centralized controller VMPX-AQ with a built-in CO₂ sensor detects the CO₂ concentration of the indoor air and automatically adjusts the airflow of the fan unit. If the air quality is poor, it automatically increases the ventilation volume. Dirty air is taken out of the room as soon as possible, and clean outside air is taken into the room. Heat exchange ventilation helps to maintain optimum warm air in the room. Indoor air quality is indicated by the centralized controller VMPX-AQ. Coronavirus countermeasures are taken by increasing or decreasing the ventilation volume in conjunction with the CO₂ concentration.
CO₂ control to reduce virus concentration
As a countermeasure against the new coronavirus drifting in the air, Seseragi-AQ (AQ=Air Quality) is a corona countermeasure ventilation system that automatically measures the carbon dioxide (CO₂) concentration, displays it, and controls ventilation. When a person breathes, CO₂ is exhaled, and if there is a lot of CO₂, it means that the air is stagnant and needs ventilation! As the CO₂ concentration decreases, the content of viruses and bacteria in the indoor air also decreases.
① Power
supply
② Air flow selection
③ Filter inspection
indicator/ Reset
④ CO₂ mode control
⑤ Heat exchange mode
⑥ Nightpurge
mode
①
②
③
④
⑤
⑥
- ① Power supply
- ② Air flow selection
- ③ Filter inspection indicator / Reset
- ④ CO₂ mode control
- ⑤ Heat exchange mode
- ⑥ Nightpurge mode
① Press and hold the power button for about 5 seconds to turn off the fan unit.
②
With the centralized controller VMPX-AQ, by pressing the air flow selection button, you can operate the machine
in four different modes.
③
When the LED of the filter inspection sign lights up, inspect the filter. After inspection, press and hold the
button ③ for about 3 seconds to reset the maintenance interval.
④ This button is used to change to CO₂ mode.
⑤ The heat exchange mode is the default operation mode.
⑥ This button is used to change to night purge mode.
Centralized controller VMPX-AQ series The VMPX-AQ series automatically starts operation when the power is turned on. Firstly, for about 5 seconds verify the status of the fans connected to the controller and confirm the internal settings and fans are recognized.
Functions of the centralized controller VMPX-AQ series
- Fan unit air supply and exhaust control
- Automatic CO₂ control (virus filter is even better!)
- Display of filter replacement time
- Operation control of 2 to 8 fans with a single controller